What 2:1 AV block is
Second-degree AV block means some P waves reach the ventricles and some do not. When exactly every second P wave is blocked, the pattern is called 2:1 AV block (two P waves to one QRS). The atria keep firing regularly from the sinus node, so the P waves march out on time. The ventricles respond to only half of them, so the ventricular rate is half the atrial rate.
The criteria used in the ECG Drills app are:
- Every second P wave is not conducted (no QRS after it).
- The PR interval is constant in the conducted beats.
- The type (Mobitz I or Mobitz II) cannot be decided from this strip.
Why you cannot call it Mobitz I or Mobitz II
The two types of second-degree block are defined by what the PR interval does across consecutive conducted beats before a P wave drops. In Mobitz I (Wenckebach) the PR gets longer beat by beat. In Mobitz II the PR stays the same. Both definitions need at least two conducted beats in a row. In 2:1 block every conducted beat is followed by a blocked P wave, so you never see two conducted beats in a row and the defining feature is invisible. The 2018 ACC/AHA/HRS bradycardia guideline lists 2:1 AV block as its own category for this reason. Full detail on the two types is in Mobitz I vs Mobitz II.
How to identify it: the 5-step method
- Rate. Count P waves and QRS complexes separately. The atrial rate is double the ventricular rate.
- Rhythm. P-to-P is regular; R-to-R is regular. (If the ratio changes, for example 2:1 then 3:2, the RR becomes irregular.)
- P waves. Upright sinus P waves, two for every QRS. One of them often hides in or on the T wave: look for a notch or a peaked T that is taller than the others.
- PR. Constant in every conducted beat. If the PR varies at random, think complete heart block instead.
- QRS. Narrow or wide. Note it: a wide QRS is one clue that the block may be below the AV node.
Measuring tips are in how to measure PR, QRS and QT.
Worked examples
Example 1. P waves every 3.75 large boxes: 300 ÷ 3.75 = 80/min. QRS every 7.5 large boxes: 300 ÷ 7.5 = 40/min. Every second P has no QRS. PR in conducted beats 4.5 small boxes = 0.18 s each time. QRS 2 small boxes = 0.08 s. Reading: 2:1 AV block, narrow QRS, ventricular rate 40/min.
Example 2. At first glance the strip looks like sinus bradycardia at 45/min. With calipers set to the P-to-P interval, you march out the P waves and find one buried in each T wave, exactly halfway between the visible P waves. Atrial rate 90/min, ventricular rate 45/min. Reading: 2:1 AV block, not sinus bradycardia.
Example 3. Atrial rate 72/min, ventricular rate 36/min, P waves regular, PR 0.16 s in conducted beats, QRS 0.14 s (3.5 small boxes). Reading: 2:1 AV block with a wide QRS. The wide QRS raises concern for block below the AV node; escalate.
Example 4. Atrial rate 80/min, ventricular rate 35/min, PR different in every beat, QRS regular. The PR is not constant and the QRS rate is not exactly half the P rate, so this is not 2:1 block. Reading: third-degree (complete) AV block.
Look-alikes
- Sinus bradycardia. One P per QRS. In 2:1 block the extra P is often hidden in the T wave.
- Blocked PACs in bigeminy. An early, differently shaped P wave fails to conduct after every sinus beat. The giveaway is that the blocked P is premature (the P-to-P is not regular). See premature atrial contractions.
- Complete heart block. PR varies at random; P and QRS have no fixed relationship.
- Atrial flutter with 2:1 conduction. Sawtooth flutter waves at about 300/min, not separate P waves with a flat baseline. See atrial flutter.
Common mistakes
- Calling it Mobitz II because the PR is constant. With 2:1 conduction a constant PR proves nothing about type.
- Missing the hidden P. Always march out the P waves with calipers before calling sinus bradycardia.
- Counting only QRS complexes. In any AV block, count the atrial and ventricular rates separately.
- Assuming it is benign. The level of block is unknown; treat it as potentially high-risk until it is clarified.
Clinical significance
Because 2:1 block can arise at the AV node or below it, its risk ranges from low to high and cannot be judged from the strip alone. The slow ventricular rate may cause symptoms. On a monitor, record the atrial and ventricular rates and the QRS width, assess the patient, and escalate according to your institution's policy. Management is outside the scope of this guide.
Practice the decision between 2:1 block, Mobitz I, Mobitz II and complete block in the drill above, or in the full ECG Drills app. See every rhythm in the ECG rhythms list.