The grid first
Every interval measurement is a box count. At the standard paper speed of 25 mm/s, one small box (1 mm) is 0.04 s and one large box (5 small boxes) is 0.20 s. So the rule for every interval is the same: count small boxes, multiply by 0.04. If an edge falls halfway through a box, count the half: 3.5 small boxes is 0.14 s.
| Interval | Starts | Ends | Normal (adult) | Small boxes |
|---|---|---|---|---|
| PR | Start of P wave | Start of QRS | 0.12–0.20 s | 3–5 |
| QRS | Start of QRS | End of QRS (J point) | Under 0.12 s (usually 0.06–0.10 s) | Under 3 |
| QT | Start of QRS | End of T wave | Rate-dependent: correct it (QTc) | Varies with rate |
If the paper speed is not 25 mm/s (some monitors allow 50 mm/s), every box is worth half as much time. Check the speed printed on the strip before you count.
Measuring the PR interval
- Find a beat where the P wave is clear and the baseline is flat.
- Put the first caliper point (or a paper edge mark) at the first deflection of the P wave from the baseline.
- Put the second point at the first deflection of the QRS, whether that is a small Q wave or the R wave.
- Count the small boxes between the points and multiply by 0.04 s.
- Repeat on two or three more beats. Note whether the PR is constant, lengthening, or varying at random.
That last step matters as much as the number. A constant PR over 0.20 s is first-degree AV block. A PR that lengthens until a P wave drops is Mobitz I; a constant PR with sudden drops is Mobitz II (Mobitz I vs Mobitz II). A PR that varies with no pattern while P and QRS each stay regular is complete heart block. A short PR (under 0.12 s) with an inverted P suggests a junctional rhythm.
Measuring the QRS
The QRS starts at the first deflection after the PR segment and ends at the J point, where the S wave (or R wave) meets the ST segment. Measure the widest-looking complex you can see clearly. Under 3 small boxes (under 0.12 s) is narrow; 3 boxes or more is wide.
A wide QRS means the ventricles are being activated slowly: a bundle branch block, a ventricular beat or rhythm (PVCs, ventricular tachycardia, idioventricular rhythms), a paced beat, or other causes. On a single lead the start or end of the QRS can sit on the baseline and be missed, so a single-lead QRS can look slightly narrower than the true 12-lead value.
Measuring the QT
The QT runs from the start of the QRS to the end of the T wave. The end of the T wave is where its downslope returns to the baseline. When the end is hard to see, a common technique is the tangent method: draw a line along the steepest part of the T-wave downslope and take the point where it crosses the baseline. If a U wave follows the T wave, do not include it unless it merges so that the two cannot be separated, and note that the QT is uncertain.
The raw QT means little on its own because it changes with heart rate. Measure the RR interval too, then correct the QT. The formulas and cut-offs are in the QTc calculation guide. A QTc above 500 ms is associated with a higher risk of torsades de pointes.
Worked examples
Example 1: PR. The P wave starts on a heavy line; the QRS starts 4 small boxes later. PR = 4 × 0.04 = 0.16 s. Normal (0.12–0.20 s).
Example 2: long PR. P start to QRS start is 1 large box plus 2 small boxes = 7 small boxes. PR = 7 × 0.04 = 0.28 s. Over 0.20 s; check that it is the same in every beat and that every P is followed by a QRS before calling first-degree AV block.
Example 3: QRS. The QRS spans 3.5 small boxes. QRS = 3.5 × 0.04 = 0.14 s. Wide (0.12 s or more).
Example 4: QT. From the start of the QRS to the end of the T wave is 2 large boxes = 10 small boxes. QT = 10 × 0.04 = 0.40 s (400 ms). The RR is 4 large boxes = 0.80 s (rate 75/min), so Bazett QTc = 0.40 ÷ √0.80, about 0.447 s (447 ms).
Example 5: the T-peak trap. A learner stops at the T-wave peak at 7 small boxes and reports QT 0.28 s. The T wave actually returns to baseline at 10 small boxes. The true QT is 0.40 s; stopping at the peak underestimated it by 0.12 s.
Calipers and the paper-edge method
Calipers are fastest, but a strip of paper works. Lay the straight edge along the baseline, mark the start and end of the interval with a pen, then slide the paper down so one mark sits on a heavy line and count the boxes to the other mark. The same marks let you check whether the PR is constant: slide them to the next beat and see if they still line up.
Common mistakes
- Starting the PR at the peak of the P wave. Always start at the first deflection from the baseline.
- Ending the PR at the R-wave peak. The PR ends where the QRS starts, including any small Q wave.
- Ending the QT at the T-wave peak. It ends where the T wave returns to the baseline.
- Forgetting the paper speed. At 50 mm/s a small box is 0.02 s.
- Measuring one beat only. Measure several; the pattern across beats often names the rhythm.
- Mixing up 0.20 s and 0.12 s. 0.20 s is the upper limit for PR; 0.12 s is the lower limit for PR and the cut-off for a wide QRS.
Practice measuring on fresh strips in the drill above, then put the numbers to work in the ECG Drills app. For every rhythm the measurements point to, see the ECG rhythms list.