What second-degree AV block is
In second-degree AV block the atria fire normally, but some atrial impulses do not reach the ventricles. On the strip you see P waves at a regular rate, and some of them are not followed by a QRS. The question is how they drop, and the answer is in the PR interval. That single measurement separates Mobitz I from Mobitz II, and its absence on a 2:1 strip is why 2:1 block gets its own name. Whether you learned it on an ECG or EKG course, the comparison is the same.
Criteria side by side
| Mobitz I (Wenckebach) | Mobitz II | 2:1 AV block | Third-degree (complete) | |
|---|---|---|---|---|
| P waves | Regular | Regular | Regular | Regular |
| PR | Lengthens until a P drops; shortest after the drop | Constant in conducted beats | Constant in conducted beats | Varies: no relationship |
| Dropped beats | After progressive PR lengthening | Sudden, without warning | Every second P | No P conducts |
| QRS rhythm | Grouped beating (regularly irregular) | Regular with pauses | Regular | Regular escape |
| QRS width | Usually narrow | Often wide | Narrow or wide | Junctional 40–60 narrow, or ventricular 20–40 wide |
| Usual level | AV node | Below the AV node | Cannot tell from the strip | Any level |
How to tell them apart: the 5-step method
- Rate. Count QRS in 6 s × 10 for the ventricular rate. Also time the P–P interval for the atrial rate. If the atrial rate is faster, P waves are being blocked.
- Rhythm. Are the QRS complexes in groups (Mobitz I), regular with occasional pauses (Mobitz II), or regular throughout (2:1 or complete block)?
- P waves. March them out with calipers. Find every P, including those hidden in T waves. Are some not followed by a QRS?
- PR. Measure the PR on every conducted beat, especially the beat before and the beat after a pause. Lengthening then resetting = Mobitz I. Identical = Mobitz II. No consistent PR at all = complete block.
- QRS. A wide QRS with a dropped beat makes a lower (infranodal) block more likely, which fits Mobitz II.
Worked examples
Example 1: Mobitz I
P waves every 20 small boxes (75/min). PR in one group: 0.20 s, 0.28 s, 0.32 s, then a P with no QRS. The next PR is 0.20 s again. The QRS is 0.08 s and arrives in groups of three. Progressive lengthening with reset: Mobitz I (Wenckebach).
Example 2: Mobitz II
P waves every 20 small boxes (75/min). PR 0.16 s on every conducted beat, before and after the pause. Every fourth P has no QRS. QRS 0.14 s (wide). Constant PR with a sudden drop: Mobitz II.
Example 3: 2:1 AV block
P waves every 18 small boxes, atrial rate 1500 ÷ 18 = 83/min. Every second P conducts with PR 0.18 s; the ventricular rate is about 42/min. Because no two conducted beats sit side by side, you cannot see whether the PR would lengthen: 2:1 AV block, type undetermined.
Example 4: complete heart block
P waves every 15 small boxes (100/min). Wide QRS every 50 small boxes (30/min). The P waves fall before, inside and after the QRS complexes with no fixed PR: third-degree AV block with a ventricular escape.
2:1 block: why the type can't be decided
Mobitz I is diagnosed by watching the PR lengthen across consecutive conducted beats. In 2:1 block there is only ever one conducted beat between blocked P waves, so that comparison is impossible. Clues can help: a narrow QRS, or Wenckebach periods elsewhere on a longer recording, suggest a nodal level; a wide QRS suggests a lower level. Still, the strip alone does not settle it, so call it "2:1 AV block" and treat it as potentially high-risk until the level is known.
How complete block differs
In complete heart block no P wave conducts. The atria and ventricles each beat regularly but independently (AV dissociation), so the PR changes at random and the atrial rate exceeds the ventricular rate. The escape is junctional (40–60/min, narrow) or ventricular (20–40/min, wide). A strip where some P waves conduct with a consistent PR is second-degree, not third-degree.
Other look-alikes
- Blocked PACs vs Mobitz II. A blocked premature atrial complex also gives a P with no QRS, but that P arrives early and often looks different. In Mobitz II the non-conducted P is on time, at the same P–P interval as the others. March out the P waves to tell them apart.
- Sinus bradycardia vs hidden 2:1 block. If the rate is about half the expected sinus rate, look inside each T wave for a buried second P. A notched or peaked T that differs from beat to beat is a clue.
- Mobitz I with long groups. When the groups are long (say 6:5), the PR lengthening between neighboring beats can be tiny. Compare the first PR in the group with the last one before the drop rather than adjacent beats.
Common mistakes
- Calling grouped beating AF. The RR changes, but the same group repeats. Look for the repeating cycle and the non-conducted P.
- Missing P waves hidden in T waves. A blocked P inside a T wave makes Mobitz II or 2:1 look like sinus bradycardia.
- Measuring only one PR. Compare the PR before and after the pause.
- Calling 2:1 block Mobitz II. Name it 2:1 unless more of the recording shows the type.
- Confusing a long fixed PR with Mobitz I. A long PR that never changes, with no dropped beats, is first-degree AV block.
Why it matters
Mobitz II, 2:1 and complete block can cause sudden severe bradycardia: assess the patient for symptoms and perfusion straight away and get a 12-lead ECG. Practice telling all four apart in the ECG Drills app, or start from the ECG Drills home page.