How to use this list
Every rhythm below is one you can practice on generated strips in the ECG Drills app. The criteria are the same ones the app uses to build each strip and grade your answer, so what you read here is what you will be tested on. They describe a single monitoring lead (lead II) at the standard paper speed of 25 mm/s, where one small box is 0.04 s and one large box is 0.20 s.
Read the list with the 5-step method in mind: rate, regularity, P waves, PR interval, QRS width. If you are new to that method, start with how to read a rhythm strip, then heart rate on an ECG and how to measure PR, QRS and QT.
Sinus rhythms (4)
| Rhythm | Key criteria | Why it matters |
|---|---|---|
| Normal sinus rhythm | Rate 60–100; Regular; Upright P before every QRS; PR 0.12–0.20 s; QRS < 0.12 s | The normal rhythm. |
| Sinus bradycardia | Sinus P before every QRS; Rate < 60; Regular | Often normal (athletes, sleep); assess for symptoms. |
| Sinus tachycardia | Sinus P before every QRS; Rate > 100 (adult usually ≤ ~150); Regular | Usually a response (pain, fever, hypovolaemia): look for the cause. |
| Sinus arrhythmia | Sinus P before every QRS; Same P shape and PR; RR varies gradually (≥ 0.12–0.16 s between longest and shortest) | Usually normal: the rate varies with breathing. |
Atrial rhythms (4)
| Rhythm | Key criteria | Why it matters |
|---|---|---|
| Sinus rhythm with PACs | Underlying sinus rhythm; Early beat with a different-looking P; QRS usually narrow, like the sinus beats (can be aberrant, or absent if the PAC is blocked); Pause usually not compensatory | Common and usually benign. |
| Supraventricular tachycardia (SVT) | Narrow QRS; Regular; Rate about 150–250; P waves not visible (or retrograde) | Can cause instability; usually abrupt onset and offset. |
| Atrial flutter | Sawtooth flutter (F) waves, atrial rate about 250–350; No isoelectric baseline between F waves; Conduction fixed (2:1, 4:1) or variable; QRS usually narrow | Stroke risk like AF; 2:1 flutter at ~150 is easy to miss. |
| Atrial fibrillation | Irregularly irregular RR; No P waves; Fibrillatory (fine or coarse) baseline; QRS usually narrow | Stroke risk; a fast ventricular rate needs attention. |
Junctional rhythms (2)
| Rhythm | Key criteria | Why it matters |
|---|---|---|
| Junctional escape rhythm | Narrow QRS; Regular; Rate 40–60; P inverted with PR < 0.12 s, hidden, or after the QRS | A backup rhythm: the sinus node has failed or slowed. |
| Accelerated junctional rhythm | Narrow QRS; Regular; Rate 60–100; P inverted with PR < 0.12 s, hidden, or after the QRS | Consider digoxin toxicity, ischaemia, post-cardiac surgery. |
Ventricular rhythms (6)
| Rhythm | Key criteria | Why it matters |
|---|---|---|
| Sinus rhythm with PVCs | Underlying sinus rhythm; Early wide (≥ 0.12 s) bizarre QRS with no P before it; T wave opposite the QRS; Usually a full compensatory pause | Common; frequent or patterned PVCs need assessment. |
| Idioventricular rhythm | Wide QRS; No P waves related to the QRS; Rate 20–40; Regular | Last-resort escape rhythm; often poor perfusion. |
| Accelerated idioventricular rhythm (AIVR) | Wide QRS; No P waves related to the QRS; Rate about 50–110 (older texts 40–100); Regular | Classic after reperfusion; usually self-limiting. |
| Monomorphic ventricular tachycardia | ≥ 3 consecutive wide QRS complexes; Rate > 100 (usually 120–250); Uniform QRS shape; Regular | Life-threatening: check the patient and pulse. |
| Ventricular fibrillation | Chaotic irregular deflections; No identifiable P, QRS or T; Coarse or fine amplitude | Cardiac arrest rhythm. Check the patient first. |
| Asystole | No ventricular activity (flat line); P waves may be present (ventricular standstill); Confirm in another lead, check gain and connections | Cardiac arrest rhythm. Fine VF can mimic it: check leads and gain. |
AV blocks rhythms (5)
| Rhythm | Key criteria | Why it matters |
|---|---|---|
| First-degree AV block | Sinus rhythm; PR > 0.20 s and constant; Every P conducted | Usually benign; watch for progression. |
| Second-degree AV block, Mobitz I (Wenckebach) | Regular P waves; PR lengthens progressively until a P is not conducted; PR after the dropped beat is the shortest; Grouped beating | Usually AV-nodal and more benign than Mobitz II. |
| Second-degree AV block, Mobitz II | Regular P waves; PR constant in conducted beats; Sudden non-conducted P; QRS often wide | Can progress suddenly to complete heart block. |
| 2:1 AV block | Every second P not conducted; PR constant in conducted beats; Type (Mobitz I or II) cannot be decided from this strip | Treat as potentially high-risk until the level of block is known. |
| Third-degree (complete) AV block | P waves regular, QRS regular; No relationship between P and QRS (PR varies); Atrial rate faster than ventricular rate; Escape: junctional 40–60 narrow or ventricular 20–40 wide | Unstable escape rhythm: urgent assessment. |
Rhythms worth knowing that are not generated in the app
- Torsades de pointes: polymorphic VT whose QRS amplitude twists around the baseline, in the setting of a long QT. See torsades de pointes.
- Pulseless electrical activity (PEA): an organized rhythm on the monitor but no palpable pulse. It is a clinical diagnosis, not a strip pattern. See asystole and PEA.
- ST elevation: not a rhythm, but often spotted on a monitor first. See ST elevation basics.
Worked examples: using the list
Example 1. Strip: rate 7 QRS in 6 s = 70/min, irregularly irregular, no P waves, wavy baseline, QRS 0.08 s (2 small boxes). Only one rhythm in the list has "irregularly irregular" and "no P waves" together: atrial fibrillation.
Example 2. Strip: regular P waves at 75/min, regular QRS at 38/min, wide QRS 0.14 s (3.5 small boxes), PR varies from beat to beat. Regular P and regular QRS with no relationship between them means complete heart block; the slow wide QRS is a ventricular escape. Reading: third-degree AV block with a ventricular escape rhythm.
Example 3. Strip: P waves regular, every second P is not followed by a QRS, PR 0.18 s (4.5 small boxes) in every conducted beat. That matches the 2:1 AV block line exactly; the list warns you that Mobitz type cannot be decided from this strip.
Example 4. Strip: regular narrow QRS at 150/min, no visible P waves. Two lines fit: SVT and atrial flutter with 2:1 conduction. Look for flutter waves hidden in the T waves before you choose. This is why the groups matter: rhythms in the same group share most criteria and differ in one.
Telling neighbours apart
Most errors happen between rhythms in the same group, so learn the one feature that separates each pair:
- Sinus bradycardia vs junctional escape: an upright P with a normal PR before each QRS means sinus; an inverted, hidden or late P means junctional.
- Atrial fibrillation vs atrial flutter with variable block: chaotic baseline vs a repeating sawtooth.
- PACs vs PVCs: early P and usually narrow QRS vs no P and wide QRS. See PACs and PVCs.
- Idioventricular vs AIVR vs VT: all wide and regular without related P waves; the rate decides (about 20–40, about 50–110, above 100). The AIVR band differs between sources, which is why the app generates strips safely inside every cited range.
- Mobitz I vs Mobitz II vs 2:1: lengthening PR vs constant PR vs every second P blocked. See Mobitz I vs Mobitz II.
- Fine VF vs asystole: check gain, leads and a second lead before you call a flat line. See ventricular fibrillation.
Where sources disagree
A few cut-offs differ between textbooks and guidelines. The lower limit of normal sinus rate is 60/min in most US nursing teaching but 50/min in the 2018 ACC/AHA/HRS bradycardia guideline. The sinus arrhythmia threshold is about 0.12 s in StatPearls and 0.16 s in other texts. The coarse-versus-fine VF cut-off is a teaching convention with no outcome evidence. Where this happens the practice app stays inside every cited range, so the answer key is right whichever textbook you learned from.
Common mistakes
- Naming the rhythm before measuring. Pattern-matching a strip from memory is how a 2:1 flutter gets called sinus tachycardia.
- Forgetting the underlying rhythm. Ectopic beats are added to a rhythm: "sinus rhythm with PACs", not just "PACs".
- Treating the monitor, not the patient. Artifact can look like VF and a normal-looking rhythm can be PEA.
- Using one lead to rule things out. A flat line or a missing P wave should be checked in a second lead.
Practice the whole list in mixed order in the ECG Drills app, or start with one group at a time.