What atrial fibrillation is
In atrial fibrillation (AF) the atria stop contracting as a unit. Hundreds of disorganized impulses per minute wander through the atrial tissue, so there is no single atrial wave and no P wave. The AV node receives a constant barrage and lets some impulses through at irregular moments. The result on a rhythm strip is a ventricular rhythm with no pattern: irregularly irregular.
AF is the most common sustained arrhythmia in adults, and it is the rhythm most new readers both over-call and under-call. Any irregular strip gets labeled AF, and coarse AF or fast AF can be missed. The fix is to check three features every time.
Criteria
| Feature | Atrial fibrillation |
|---|---|
| Rate | Any; describe it (see below) |
| Rhythm | Irregularly irregular: no repeating pattern in the RR intervals |
| P waves | None; replaced by a fibrillatory (f-wave) baseline, fine or coarse |
| PR interval | Not measurable |
| QRS | Usually narrow (< 0.12 s); wide with a bundle branch block, aberrancy or an accessory pathway |
Rate labels. These describe the strip; they are not treatment targets. A ventricular rate over 100/min is commonly called AF with rapid ventricular response (RVR); 60–100 is often called controlled or rate-controlled; under 60 is slow ventricular response. The 2023 ACC/AHA/ACCP/HRS AF guideline discusses rate-control targets for treatment; those are clinical decisions and are not taught here.
How to identify it: the 5-step method
- Rate. Count the QRS in 6 seconds × 10. Do not use 300 ÷ large boxes or 1500 ÷ small boxes on one RR interval: in AF each interval gives a different answer. See heart rate on an ECG.
- Rhythm. March the RR intervals with calipers. In AF no two consecutive intervals match and no group repeats.
- P waves. Look for a consistent P before each QRS. In AF there is none, just an uneven, wavy or almost flat baseline.
- PR interval. With no P waves there is no PR to measure. If you can measure a constant PR, it is not AF.
- QRS. Usually narrow. An occasional wide beat may be aberrant conduction or a PVC.
Worked examples
Example 1. A 6-second strip has 13 QRS complexes at uneven intervals: 13 × 10 = 130/min. No P waves, a wavy baseline, QRS 0.08 s. Atrial fibrillation with rapid ventricular response.
Example 2. 8 QRS in 6 s → 80/min. The RR intervals measure 15, 21, 18, 13, 24 and 17 small boxes: no pattern. The baseline is almost flat with tiny irregular waves. Fine AF, rate 80/min (controlled ventricular response). If you had used the first RR, 1500 ÷ 15 = 100, you would have overestimated the rate.
Example 3. The RR varies, but every QRS has the same upright P in front of it with a PR of 0.16 s, and the intervals lengthen and shorten smoothly. That is sinus arrhythmia, not AF: there are P waves.
Look-alikes and how to tell them apart
| Rhythm | Key difference from AF |
|---|---|
| Atrial flutter (especially variable block) | Identical, evenly spaced sawtooth waves at about 300/min; RR intervals are multiples of the flutter cycle. |
| Sinus arrhythmia | An upright P before every QRS, constant PR, RR changes gradually with breathing. |
| Sinus rhythm with PACs | Regular sinus beats interrupted by early beats that have their own (different) P wave. |
| Sinus rhythm with PVCs | Underlying regular sinus beats with P waves; the early beats are wide with no P. |
| Multifocal atrial tachycardia | Irregular, but with visible P waves of at least three shapes (needs a careful look). |
Coarse AF versus flutter in practice
Coarse fibrillatory waves can be large enough to look like flutter waves or even P waves. Set your calipers on two neighboring waves and march them along. In flutter the next wave lands exactly where the calipers predict, across the whole strip. In coarse AF the waves drift, change height and shape, and the RR intervals have no relationship to them.
Common mistakes
- Calling AF flutter. The ECG Drills feedback: the baseline waves vary in size, shape and timing and the RR intervals are irregularly irregular; flutter waves are identical and evenly spaced.
- Calling AF sinus arrhythmia. Sinus arrhythmia has an upright P before every QRS. AF has no P waves, only a fibrillatory baseline.
- Calling sinus arrhythmia AF. The reverse: identical P waves with a constant PR rule AF out.
- Seeing a pattern in chaos. If the RR has no repeating group, it is irregularly irregular. A repeating group points to Mobitz I or patterned ectopy instead.
- Timing one RR interval. The rhythm is irregular, so one interval doesn't represent the rate. Count over 6 seconds.
Clinical significance (one line)
AF raises stroke risk and a fast ventricular rate can compromise the patient, so new or fast AF needs prompt clinical assessment and usually a 12-lead ECG.
Practice it