Telemetry · ICU · Paramedic

EKG practice strips that make you measure, not guess

Unlimited lead II monitor strips. Use real calipers for rate, PR and QRS, then name the rhythm. When you get it wrong, the feedback points to the step you most likely misread.

  • Feedback that names the mistake
  • A new strip every time

Loading…

Why rhythm strips are hard, and how practice fixes it

Most rhythm mistakes are not knowledge gaps. They are skipped steps: calling AF without looking for flutter waves, calling Wenckebach without measuring each PR, calling a flat line asystole when it is fine VF. Fixed strip banks get memorised by picture, so they never train the steps.

ECG Drills generates a new strip every time from exact beat timings. You measure with calipers, answer, and get feedback written for the specific mistake you made, with the P waves and QRS complexes marked on the strip.

The 5-step method

  1. Rate: QRS complexes in 6 seconds × 10 (or 1500 ÷ small boxes if regular).
  2. Rhythm: march out the RR intervals. Regular, regularly irregular, or irregularly irregular?
  3. P waves: upright and one before every QRS? Inverted, absent, sawtooth, or more P than QRS?
  4. PR interval: 0.12–0.20 s, and is it constant?
  5. QRS: narrow (< 0.12 s) or wide? Then name the rhythm.

Rhythm criteria cheat sheet

RhythmRateKey features (lead II)
Normal sinus rhythm60–100Regular; upright P before every QRS; PR 0.12–0.20 s; QRS < 0.12 s
Sinus bradycardia / tachycardia< 60 / > 100As sinus rhythm, slower or faster
Atrial fibrillationVariesIrregularly irregular; no P waves; fibrillatory baseline
Atrial flutterAtrial ~300Sawtooth F waves; 2:1, 4:1 or variable conduction
SVT~150–250Narrow, regular, no visible P waves
Junctional rhythms40–60 / 60–100Inverted P with PR < 0.12 s, hidden, or after the QRS
PACsUnderlyingEarly beat with a different-shaped P wave; QRS usually narrow
PVCsUnderlyingEarly wide (≥ 0.12 s) bizarre QRS, no P before it, T opposite; usually a full compensatory pause
Idioventricular / AIVR20–40 / ~50–110Wide QRS, no related P waves, regular
Ventricular tachycardia> 100≥ 3 wide QRS in a row, uniform, P waves absent or dissociated
Ventricular fibrillationNoneChaotic deflections, no identifiable QRS; coarse or fine
AsystoleNoneFlat line (P waves alone = ventricular standstill); confirm in another lead and check gain
First-degree AV blockUnderlyingPR > 0.20 s, constant, every P conducted
Mobitz I (Wenckebach)UnderlyingPR lengthens until a P is dropped
Mobitz IIUnderlyingConstant PR, sudden dropped P
Third-degree blockEscape 20–60P and QRS regular but unrelated; PR varies

Teaching criteria; textbooks differ on some cut-offs (for example AIVR 40–100 or 50–110). Educational practice only.

Mistakes ECG Drills catches

Flutter called AF

The QRS is irregular, but the baseline shows regular sawtooth waves.

Mobitz II called Wenckebach

The PR before and after the dropped beat is the same. That one can progress to complete block.

Fine VF called asystole

Low-amplitude chaos is not a flat line. Check leads and gain.

Counting P waves as the heart rate

The monitor rate is the ventricular rate: count QRS complexes.

Pricing

ECG Drills pass

Reading the grid and measuring intervals (Units 1–2) are free. The rhythm units and mixed strips are in the pass: $29 · 4 months · one payment · no subscription.

Start practicing free

Frequently asked questions

How do you read an EKG rhythm strip?

Use the same five steps every time: 1) rate, 2) regularity, 3) P waves (is there one before every QRS?), 4) PR interval, 5) QRS width. Then name the rhythm. ECG Drills makes you measure each step with calipers before you name it.

How do you calculate heart rate on a 6-second strip?

Count the QRS complexes in 6 seconds and multiply by 10. It works for irregular rhythms. For regular rhythms you can also divide 1500 by the number of small boxes between two R waves, or 300 by the number of large boxes.

How big is a box on ECG paper?

At the standard 25 mm/s, one small (1 mm) box is 0.04 s and one large (5 mm) box is 0.20 s. Vertically, 10 mm is 1 mV.

What is a normal PR interval and QRS width?

PR is normally 0.12–0.20 s (3–5 small boxes). A normal QRS is under 0.12 s (3 small boxes). A PR over 0.20 s that stays constant is first-degree AV block.

How do you tell Mobitz I from Mobitz II?

Measure every PR. In Mobitz I (Wenckebach) the PR gets longer until a P wave is not conducted, then resets. In Mobitz II the PR stays the same and a P wave suddenly fails to conduct. With 2:1 conduction you cannot tell which it is from the strip.

How do you tell atrial flutter from atrial fibrillation?

Flutter has identical, evenly spaced sawtooth F waves (about 300 per minute). Fibrillation has a chaotic baseline with no organised atrial waves and an irregularly irregular ventricular rhythm.

Are the strips real?

They are generated by a rhythm engine from exact beat timings, so every answer key comes from the timings, not from someone's reading of a picture. Each strip is new, so you cannot memorise them.

Who is ECG Drills for?

Telemetry, ICU and step-down nurses in orientation, monitor technicians preparing for a rhythm test, paramedic and nursing students, and anyone who needs to read monitor strips.

Can I use ECG Drills on real patients?

No. ECG Drills is educational practice only with simulated strips. It is not a clinical decision tool. Always assess the patient and follow your institution's policies.

Educational practice only. Simulated strips; not a clinical decision tool.