Two arrest rhythms that cannot be shocked
Cardiac arrest rhythms fall into two groups. Ventricular fibrillation and pulseless ventricular tachycardia are shockable. Asystole and pulseless electrical activity (PEA) are not. Telling them apart quickly is a core monitoring skill, and the ECG is only half the picture: you always pair what the monitor shows with whether the patient has a pulse.
| Feature | Asystole | PEA | Fine VF |
|---|---|---|---|
| Monitor | Flat line (P waves may persist) | Organized rhythm (any) | Low-amplitude chaotic waves |
| QRS complexes | None | Present | None identifiable |
| Pulse | None | None (defining) | None |
| Diagnosis from strip alone? | Only after confirmation checks | No: needs a pulse check | Yes, if visible at proper gain |
Asystole
The criteria used in the ECG Drills app are:
- No ventricular activity (flat line).
- P waves may be present (ventricular standstill).
- Confirm in another lead, check gain and connections.
A true flat line is rarely perfectly straight; small baseline drift is normal. The important question is whether there are any QRS complexes or any fibrillation waves. Before naming asystole, run the confirmation checks:
- Leads and connections. Is every electrode attached and the cable plugged in? A disconnected lead produces a flat line in a patient who may be fine.
- Gain. Increase the size (gain) of the trace. Fine VF may appear.
- Another lead. VF waves can be small in one lead and visible in another.
Pulseless electrical activity (PEA)
PEA is not a single strip pattern. It is any organized electrical rhythm, other than VF or pulseless VT, in a patient who is unresponsive with no palpable pulse. The monitor might show sinus rhythm, a slow wide rhythm, a junctional rhythm or anything else that looks organized. The heart's electrical system is working, but the heart is not producing a pulse.
This is why the ECG Drills app does not generate a "PEA strip": the same strip could belong to a patient who is talking to you. PEA is diagnosed at the bedside by combining the monitor with a pulse check.
Worked examples (described scenarios)
Example 1. A flat line in lead II. Leads are attached, gain is increased, and lead I is also flat. No P waves, no QRS. The patient is unresponsive and pulseless. Reading: asystole. Call for help, start CPR, follow ACLS.
Example 2. A flat line in lead II, but on increasing the gain small irregular waves appear, clearer in lead I. Reading: fine ventricular fibrillation, not asystole. See ventricular fibrillation.
Example 3. Regular P waves at 70/min on an otherwise flat line, with no QRS complexes after them. Reading: ventricular standstill (P-wave asystole).
Example 4. The monitor shows a regular narrow-complex rhythm at 80/min with P waves. The patient is unresponsive and no carotid pulse is felt. Reading: PEA. The rhythm label alone ("sinus rhythm") would have been dangerously wrong.
Example 5. A flat line on the monitor, but the patient is sitting up and asking for water. Reading: lead disconnection or equipment problem, not asystole. Fix the leads.
Why the distinction matters
Arrest rhythms are sorted into shockable and non-shockable because the immediate response differs. Calling fine VF "asystole" can mean a shockable rhythm is missed; calling a lead disconnection "asystole" can start an arrest response for a patient who is fine. Calling PEA "sinus rhythm" can delay CPR in a patient who has no circulation. Each of these errors comes from trusting the monitor without checking the patient or the equipment, which is why the confirmation steps on this page are worth practicing until they are automatic.
During resuscitation, the rhythm is reassessed repeatedly, and it can change from one arrest rhythm to another: asystole to VF, VF to PEA, or PEA to a rhythm with a pulse. Recognizing each one quickly at every check is the skill this page and the drill build.
Common mistakes
- Calling a flat line asystole without checks. Leads, gain, second lead, every time.
- Treating the rhythm label as the patient's status. A normal-looking rhythm does not prove a pulse.
- Forgetting ventricular standstill. P waves without QRS complexes are still asystole for arrest purposes; do not mistake them for a working rhythm.
- Confusing PEA with a slow rhythm with a pulse. A slow wide escape rhythm, such as in complete heart block, is PEA only if there is no pulse.
What to do (scope of this guide)
This page teaches recognition only. In either rhythm the patient is in cardiac arrest: call for help, start CPR and follow ACLS and your institution's emergency procedures. The current algorithm, including the search for reversible causes, is set out in the AHA adult advanced life support guideline in the references. This guide is not a substitute for resuscitation training.
Practice telling asystole from fine VF and VT in the drill above, then mix it with every other rhythm in the ECG Drills app. See the full ECG rhythms list, or brush up on torsades de pointes.