What the QTc is
The QT interval is the time from the start of ventricular depolarization (start of the QRS) to the end of repolarization (end of the T wave). It shortens as the heart rate rises and lengthens as it slows, so a raw QT cannot be compared between a patient at 50/min and the same patient at 110/min. The corrected QT (QTc) estimates what the QT would be at 60/min, where the RR interval is exactly 1.00 s. That is why every formula divides by some function of RR, and why that function equals 1 when RR is 1 second.
The formulas
| Formula | QTc = | Notes |
|---|---|---|
| Bazett | QT ÷ √RR | Most widely used; adequate at about 60–100/min |
| Fridericia | QT ÷ ∛RR (cube root) | Less rate error; often preferred outside 60–100/min |
RR is in seconds. QT can be in seconds or milliseconds; the QTc comes out in the same unit.
Step by step on a rhythm strip
- Rate and rhythm. Use the 5-step method: rate, rhythm, P waves, PR, QRS. QTc is most reliable on a regular rhythm.
- Measure the QT. Start at the beginning of the QRS. End where the T wave returns to baseline. Count small boxes × 0.04 s. Example: 10 small boxes = 0.40 s = 400 ms.
- Measure the RR before that beat, in seconds. Small boxes × 0.04, or 60 ÷ heart rate (see heart rate calculation). Example: 20 small boxes = 0.80 s (75/min).
- Take the root. Square root for Bazett, cube root for Fridericia.
- Divide QT by the root and round to whole milliseconds.
- Compare with the cut-offs below, and note which formula you used.
Worked examples
Example 1: normal rate (75/min)
QT 400 ms, RR 0.80 s. Bazett: √0.80 = 0.894; 400 ÷ 0.894 = 447 ms. Fridericia: ∛0.80 = 0.928; 400 ÷ 0.928 = 431 ms. A 16 ms difference at a near-normal rate.
Example 2: fast rate (120/min)
QT 320 ms, RR 0.50 s. Bazett: √0.50 = 0.707; 320 ÷ 0.707 = 453 ms. Fridericia: ∛0.50 = 0.794; 320 ÷ 0.794 = 403 ms. Bazett makes this look borderline-prolonged; Fridericia does not. This is Bazett over-correcting at a fast rate.
Example 3: slow rate (50/min)
QT 480 ms, RR 1.20 s. Bazett: √1.20 = 1.095; 480 ÷ 1.095 = 438 ms. Fridericia: ∛1.20 = 1.063; 480 ÷ 1.063 = 452 ms. Here Bazett under-corrects and gives the lower number.
Example 4: exactly 60/min
QT 420 ms, RR 1.00 s. Every root of 1 is 1, so QTc = QT = 420 ms by either formula. This is a quick self-check for your arithmetic.
Doing the roots without a calculator
Most people use a calculator or the monitor's built-in QTc, but it helps to know roughly what the root should be so you can spot a slip. For Bazett, RR 0.64 s has a square root of 0.80, RR 0.81 s a root of 0.90, RR 1.00 s a root of 1.00, and RR 1.21 s a root of 1.10. For Fridericia, the cube root of 0.512 is 0.80 and of 1.331 is 1.10. If your root is greater than 1 when the rate is above 60/min, or less than 1 when the rate is below 60/min, something has gone wrong: the RR is probably in the wrong unit. A useful sense check is direction: at rates above 60/min the QTc is always longer than the measured QT, and below 60/min it is always shorter. Fridericia moves the number less than Bazett in both directions.
Cut-offs (and where sources differ)
| Source | Men: prolonged above | Women: prolonged above |
|---|---|---|
| LITFL (common teaching) | 440 ms | 460 ms |
| AHA/ACCF/HRS 2009 standardization statement | 450 ms | 460 ms |
The two sources differ on the male cut-off (440 vs 450 ms); this page states both rather than picking one. Both agree that a QTc above 500 ms carries a higher risk of torsades de pointes. Local policy decides which numbers trigger action.
Bazett at fast and slow rates
Bazett over-corrects above about 100/min, so a fast patient can look prolonged when they are not, and under-corrects below about 60/min, so a slow patient with a genuinely long QT can look normal. Between about 60 and 100/min it is adequate. Outside that range, LITFL recommends Fridericia (or Framingham). The drill lets you switch formula in Settings so you can see the difference on the same numbers.
Look-alikes and pitfalls in measurement
- T wave vs U wave. A separate U wave after the T is not part of the QT. If they merge, measurement is uncertain; a 12-lead ECG is needed.
- Wide QRS. A bundle branch block lengthens the QT without a repolarization problem; interpret with care.
- Irregular rhythm. In AF or with ectopics, average several beats rather than correcting one.
Common mistakes
- Stopping at the T-wave peak. QT ends where the T wave returns to baseline.
- Dividing by RR without the root. Bazett divides by the square root, Fridericia by the cube root, of RR in seconds.
- Using RR in milliseconds. Convert to seconds first.
- Mixing formulas. Compare serial QTc values with the same formula.
Why it matters
A long QTc is a flag for arrhythmia risk that prompts a 12-lead ECG and a look at the patient, medicines and electrolytes; it is not a diagnosis from one strip. Practice measuring and correcting in the ECG Drills app, or start at the ECG Drills home page.