Third-Degree Heart Block on ECG (Complete Heart Block)

Short answer: Third-degree (complete) heart block means no atrial impulse reaches the ventricles. On the strip, P waves and QRS complexes are each regular but unrelated, so the PR interval keeps changing. The atrial rate beats the ventricular rate, for example P at 80/min and QRS at 40/min. The escape is junctional (40–60, narrow) or ventricular (20–40, wide).

Try it now: free practice strips

Loading practice…

What complete heart block is

In third-degree AV block the electrical path between the atria and the ventricles is cut. The sinus node keeps firing and the atria keep producing P waves at their own rate. The ventricles, receiving nothing, are driven by a backup (escape) pacemaker lower down. Two independent rhythms now share one strip. That is AV dissociation, and on a lead II monitor strip (EKG or ECG, the same thing) it is what you are looking for.

FeatureComplete heart block
P wavesPresent, regular (march out on time)
QRS rhythmRegular
P–QRS relationshipNone: PR varies, P waves fall anywhere, some hidden in QRS or T
RatesAtrial rate faster than ventricular rate
EscapeJunctional: narrow QRS, about 40–60/min. Ventricular: wide QRS (≥ 0.12 s), about 20–40/min

How to identify it: the 5-step method

  1. Rate. Count both rates. Count QRS complexes in 6 seconds × 10 for the ventricular rate, then count P waves the same way for the atrial rate. In complete block the P count is higher.
  2. Rhythm. RR intervals are regular. Calipers or a paper edge on the PP intervals also show them regular.
  3. P waves. Mark each P wave, including ones that deform a T wave or sit inside a QRS. If they march through at a steady PP interval regardless of the QRS, the atria are independent.
  4. PR interval. Measure the PR before every QRS. In complete block it changes with no pattern: short, long, sometimes the P falls after the QRS.
  5. QRS. Narrow (< 0.12 s, under 3 small boxes) suggests a junctional escape; wide (≥ 0.12 s) suggests a ventricular escape.

For the general method, see how to read a rhythm strip.

Worked examples

Example 1. 8 P waves and 4 QRS complexes in 6 seconds: atrial rate 80/min, ventricular rate 40/min. RR regular at 7.5 large boxes (300 ÷ 7.5 = 40). PR measures 0.14 s, then 0.30 s, then a P buried in the T wave. QRS 0.08 s (2 small boxes). Reading: third-degree AV block with a narrow (junctional) escape at 40/min.

Example 2. 9 P waves and 3 QRS complexes in 6 seconds: atrial 90/min, ventricular 30/min. QRS 0.16 s (4 small boxes), PR varies. Reading: third-degree AV block with a wide (ventricular) escape at 30/min. This is the less reliable escape, so the patient needs urgent assessment.

Example 3 (a trap). 8 P waves, 4 QRS. Every QRS is preceded by a P with PR 0.16 s, and every other P has no QRS. The PR is constant, so this is 2:1 AV block, not complete block. The ratio of rates alone cannot tell them apart; the PR can.

Look-alikes and how to tell them apart

  • Mobitz II. Regular P waves, a constant PR in every conducted beat, and a sudden dropped QRS. If you can find even two QRS complexes with the same PR after a P, some beats are conducting. Compare in Mobitz I vs Mobitz II.
  • 2:1 AV block. Atrial rate exactly double the ventricular rate, every conducted P with the same PR. The level of block cannot be decided from the strip, so it is treated as potentially high risk, but it is not complete block.
  • Junctional escape rhythm. Narrow, regular, 40–60, but with no independent faster P waves marching through. P waves are absent, inverted with a short PR, or just after the QRS. See junctional rhythm.
  • First-degree AV block. Long but constant PR (> 0.20 s) and every P conducted. Despite the name, nothing is blocked. See first-degree AV block.

Marching out P waves

The single most useful skill for AV blocks is marching out P waves. Find two clear consecutive P waves, set calipers (or mark a paper edge) to that PP interval, and step it along the strip. Every place it lands should have a P wave, visible or hiding. Then, for each QRS, ask whether the P before it has the same PR as the others. Constant PR in the conducted beats means some form of second-degree block; no constant PR anywhere means complete block.

A longer strip helps. Over 6 seconds at slow ventricular rates you may only see three or four QRS complexes, which is too few to be sure the PR is truly random. Ask for a longer run when you can.

Common mistakes

  • Missing hidden P waves. If you only count the obvious P waves, the atrial rate looks equal to the ventricular rate. Use the PP interval to predict where the next P should be and look for a notch in the T or QRS.
  • Calling 2:1 block "complete" because half the P waves are dropped. Check the PR of the conducted beats first.
  • Calling it complete block when a P happens to sit before a QRS. By chance, some P waves will land at a normal-looking PR. Measure several beats; one normal PR does not prove conduction.
  • Calling any AV dissociation complete block. If the ventricular rate is faster than the atrial rate (for example an accelerated junctional rhythm overtaking a slow sinus), the P waves may simply not get a chance to conduct.

Clinical significance

Complete heart block depends on an escape pacemaker that may be slow or may fail, so assess the patient first (responsiveness, pulse, perfusion, symptoms) and escalate per local protocol. Management is outside the scope of this guide.

Practice the four look-alikes above in the drill, or open the full ECG Drills app. More guides at ECG Drills.

Frequently asked questions

What are the ECG criteria for third-degree heart block?

Regular P waves, regular QRS complexes, and no relationship between them, so the PR interval varies from beat to beat. The atrial rate is faster than the ventricular rate. The QRS comes from an escape pacemaker: junctional (narrow, about 40–60/min) or ventricular (wide, about 20–40/min).

How do you tell complete heart block from Mobitz II?

In Mobitz II, every conducted beat has the same PR interval and a P wave suddenly fails to conduct. In complete heart block no P wave conducts, so there is no constant PR at all. March out the P waves and measure the PR before each QRS: constant means Mobitz II, random means complete block.

Is third-degree heart block the same as AV dissociation?

Not exactly. Complete heart block always causes AV dissociation, but AV dissociation can also happen without block, when a junctional or ventricular rhythm runs faster than the sinus node. The key for complete block is that the atrial rate is faster than the ventricular rate and still nothing conducts.

Is complete heart block an emergency?

It can be. The escape rhythm may be slow and unreliable, especially a wide ventricular escape at 20–40/min. On any strip that looks like complete block, assess the patient first (responsiveness, pulse, blood pressure, symptoms) and escalate per your local protocol. This guide does not cover treatment.

Why is the QRS wide in some complete heart blocks and narrow in others?

Width depends on where the escape pacemaker sits. A junctional escape above the bundle branches uses the normal conduction system, so the QRS is narrow at about 40–60/min. A ventricular escape below the block spreads cell to cell, so the QRS is wide at about 20–40/min.

References

  1. LITFL ECG Library: AV block, 3rd degree (complete heart block)
  2. LITFL Eponym Library: Second-degree atrioventricular block
  3. Kusumoto FM et al. 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay. Circulation 2019;140:e382–e482
  4. LITFL ECG Library: Junctional Escape Rhythm

Teaching criteria; textbooks differ on some cut-offs. Educational practice only: not a clinical decision tool. Always assess the patient and follow your institution's policies.