ABG vs VBG: what changes and what doesn't

A venous blood gas (VBG) tracks arterial pH and bicarbonate closely: venous pH runs about 0.03 lower. Venous PCO2 agrees poorly, though a normal value helps exclude high arterial CO2. Venous PO2 cannot assess oxygenation. Arterial pH normal is 7.35–7.45. Follow your facility's ranges.

Try it now

Flag the ABG values · free, no sign-up

LABORATORY RESULT

71-year-old female, outpatient clinic

TestResult
PaCO243 mmHg
Typical adult ranges; labs vary. Follow your facility's reference ranges. Educational practice only.

How do you classify this result (PaCO2)?

Arterial blood gas values used in Labs Drills (typical adult)

TestTypical adult rangeCritical (Labs Drills list)
pH (arterial)7.35–7.45below 7.20 or above 7.60
PaCO235–45 mmHgbelow 20 mmHg or above 70 mmHg
HCO3- (arterial)22–26 mEq/L–
PaO280–100 mmHgbelow 40 mmHg
SaO295–100%–

Typical adult ranges; labs vary. Follow your facility's reference ranges and policies.

Why venous gases are used

An arterial puncture is painful and carries risks; a venous sample can often be taken with routine bloods or from an existing line. Emergency departments use venous gases widely for metabolic problems such as diabetic ketoacidosis, where pH and bicarbonate drive decisions.

All the reference values in Labs Drills (table above) are arterial: pH 7.35–7.45, PaCO2 35–45 mmHg, HCO3- 22–26 mEq/L, PaO2 80–100 mmHg. MedlinePlus describes the arterial test; a venous result has to be read with the differences below in mind.

pH and bicarbonate: close agreement

Bloom and colleagues (2014) pooled emergency-department studies: venous pH was on average 0.033 lower than arterial, with narrow limits of agreement, and venous bicarbonate was on average 1.03 mmol/L higher. Byrne and colleagues (2014; 18 studies, 1768 adults) found arterial pH typically 0.03 higher than venous.

Agreement is best near normal values. For trending acidosis (for example, is the DKA patient's pH improving?) a venous gas is usually adequate. Your facility decides which tests are acceptable for which decisions.

PCO2: poor agreement, but a useful screen

Venous PCO2 was on average 4.41 mmHg higher than arterial in the Bloom meta-analysis, but individual differences were wide (95% limits of agreement -20.4 to +25.8 mmHg). You cannot convert one to the other reliably.

The useful part is negative: the same review found that a normal peripheral venous PCO2 has a good negative predictive value for a normal arterial PCO2, so it can screen out hypercapnia. A high venous PCO2 needs an arterial gas if the decision depends on it, for example in suspected CO2 retention in COPD.

Oxygen: use the arterial gas or pulse oximetry

Venous oxygen reflects what the tissues left behind, not what the lungs delivered. Byrne found arterial PO2 typically 36.9 mmHg higher than venous, with wide variability (95% CI 27.2 to 46.6 mmHg). A venous PO2 is not used to judge oxygenation.

Assess oxygenation with SpO2 and, when needed, an arterial gas (PaO2 80–100 mmHg, SaO2 95–100%). The A–a gradient and P/F ratio need an arterial PaO2.

Lactate

In the Bloom meta-analysis venous lactate was on average 0.25 mmol/L higher than arterial; agreement was poorer at abnormal values, but a normal venous lactate made a normal arterial value likely.

What to report with a blood gas

State the sample type first (arterial or venous), then the pH, PCO2 and bicarbonate, then the patient: respiratory rate and effort, oxygen saturation and the oxygen being given, level of consciousness and the reason the gas was drawn. For a venous gas, say so explicitly so nobody reads the PO2 as hypoxemia or the PCO2 as an arterial value. If the result does not match the patient, ask whether an arterial gas should be drawn rather than acting on a doubtful number.

Central versus peripheral venous samples

Venous gases can be drawn from a peripheral vein or from a central line. The studies in both meta-analyses mostly used peripheral samples (Byrne restricted its review to peripheral venous gases). Central venous oxygen saturation is a separate measurement used in some shock protocols and should not be confused with a routine venous gas.

Sampling technique affects all gases: air bubbles, delays before analysis and a tourniquet left on for a long time can change the results. Follow your facility's procedure for collection, labelling and transport, and always label the sample type so the result is read against the right ranges.

When an arterial gas is still needed

An arterial sample is the standard when oxygenation must be measured (PaO2 for the P/F ratio or A–a gradient), when the exact PaCO2 matters (suspected hypercapnia, ventilator adjustment) and when a venous result does not fit the patient. Arterial values used in Labs Drills: PaCO2 35–45 mmHg, PaO2 80–100 mmHg.

Nursing care around an arterial puncture includes checking collateral circulation as your facility requires (some use a modified Allen test before a radial stab), applying firm pressure afterwards (longer on anticoagulants), and checking the site and the hand for bleeding, swelling and circulation.

How to study ABG versus VBG

Remember a four-line summary. pH: close (venous about 0.03–0.033 lower). Bicarbonate: close (venous about 1.03 mmol/L higher). PCO2: unreliable for an exact number, but a normal venous value helps exclude hypercapnia. PO2: do not use. Then practise reading arterial gases step by step with the ABG interpretation guide and the drill above.

Worked examples

Trending DKA on venous gases

A patient with DKA has a venous pH of 7.28.

  1. Venous pH runs about 0.033 below arterial (Bloom 2014), so the arterial pH is roughly 7.28 + 0.033 ≈ 7.31.
  2. Either way, it is below the arterial normal of 7.35–7.45: acidemia. Trend it with each venous gas as ordered.
  3. Use this as an estimate only; never write an "estimated arterial pH" in the record. Report the measured venous value with its sample type.

Drowsy COPD patient

A patient with COPD on oxygen is newly drowsy. The venous PCO2 is high.

  1. Venous PCO2 cannot be converted reliably to arterial PCO2.
  2. Report the drowsiness and the result now; anticipate an arterial gas to measure the PaCO2 and guide ventilation decisions.

Low venous PO2, normal SpO2

A venous gas shows a low PO2; SpO2 is 97% on room air and the patient is comfortable.

  1. Venous PO2 is normally much lower than arterial and does not measure oxygenation.
  2. SpO2 is within the typical arterial saturation range (95–100%); no oxygen problem is shown by this result.

Common mistakes

Reading venous PO2 as hypoxemia

Venous PO2 is always lower. Use SpO2 or an arterial PaO2 to judge oxygenation.

Converting PCO2

Venous–arterial PCO2 differences vary widely between patients. A high venous PCO2 may need an arterial gas.

Unlabelled samples

Interpret every gas by its sample type. A venous sample read against arterial ranges leads to wrong calls.

Frequently asked questions

Is a VBG the same as an ABG?

No. Venous pH and bicarbonate agree reasonably with arterial values, but venous PCO2 agrees poorly and venous PO2 does not measure oxygenation.

How much lower is venous pH?

On average about 0.03 to 0.033 lower than arterial pH in meta-analyses of adults.

Can a VBG rule out high CO2?

A normal peripheral venous PCO2 has a good negative predictive value for a normal arterial PCO2, so it can help screen out hypercapnia. A high venous value may need an arterial gas.

Can I use venous PO2 to check oxygenation?

No. Use pulse oximetry and, when needed, an arterial PaO2.

What are normal ABG values?

Typical arterial values: pH 7.35–7.45, PaCO2 35–45 mmHg, HCO3- 22–26 mEq/L, PaO2 80–100 mmHg.

Practice next

References

  1. Bloom BM, Grundlingh J, Bestwick JP, Harris T. The role of venous blood gas in the emergency department: a systematic review and meta-analysis. Eur J Emerg Med 2014;21(2):81–88doi.org/10.1097/MEJ.0b013e32836437cf
  2. Byrne AL, Bennett M, Chatterji R, Symons R, Pace NL, Thomas PS. Peripheral venous and arterial blood gas analysis in adults: are they comparable? A systematic review and meta-analysis. Respirology 2014;19(2):168–175doi.org/10.1111/resp.12225
  3. MedlinePlus: Blood gasesmedlineplus.gov/ency/article/003855.htm
  4. Berend K, de Vries APJ, Gans ROB. Physiological approach to assessment of acid–base disturbances. N Engl J Med 2014;371:1434–45. doi:10.1056/NEJMra1003327

Educational practice only; not a clinical decision tool. Typical adult ranges; labs vary. Follow your facility's reference ranges and policies. NCLEX is a registered trademark of NCSBN, used descriptively; Clinical Drills is not affiliated with NCSBN. Facts are summarised from the sources above; no text is reproduced.